TVA defends Browns Ferry after reports of equipment, operator failure

tva-defends-browns-ferry-after-reports-equipment-o
tva-defends-browns-ferry-after-reports-equipment-o tva-defends-browns-ferry-after-reports-equipment-o

MOREReport calls for nuclear safety plan overhaul

Browns Ferry Nuclear Plant had far more problems during recent tornadoes than TVA told the public after winds took down power lines and the plant went into automatic shutdown.

Tennessee Valley Authority statements after the late April tornadoes indicated everything functioned as it should when all three reactors shut down when the power they generated had nowhere to go because more than 300 monster power towers had been blown down.

But documents the utility is required to submit to the Nuclear Regulatory Commission show reactor operators became distracted while manually operating cooling water flow to the Unit 1 reactor and water began boiling off faster than it was being replaced.

Additionally, a valve failed, a diesel-driven fire pump failed, the diesel-driven generator for the security station failed, the warning sirens were lost, power to the chemical lab was lost, and an emergency diesel generator keeping cool water flowing to one of three reactors shut down because of voltage fluctuations caused by a fluid leak after a brass fitting broke.